Published 1993 | Version v1
Report

Measurement of the distribution of auto activation in lucite block

  • 1. National Inst. of Radiological Sciences, Chiba (Japan)

Description

Distribution of positron emitters induced through auto activation of 12C(135MeV/u, nominal) in Lucite were measured with coincidence counting technique. A major product was 11C and peaked at near the range of 11C calculated on the basis of energy (11/12) times that of projectiles. Dose dissipated at Bragg peak of the beam estimated to be comparable to the dose used in radiation therapy and auto activation technique can hardly be used for assessment of dose distribution. (author)

Part of:
Proceedings of the second workshop on physical and biological research with heavy ions

Additional details

Publishing Information

Imprint Title
Proceedings of the second workshop on physical and biological research with heavy ions
Imprint Pagination
56 p.
Journal Page Range
p. 7-8.
Report number
NIRS-M--90

Conference

Title
2. workshop on physical and biological research with heavy ions.
Dates
31 Aug 1992.
Place
Chiba (Japan).

Optional Information

Secondary number(s)
HIMAC--003.