Direct comparison of Neuroform and Enterprise stents in the treatment of wide-necked intracranial aneurysms
Creators
- 1. Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA (United States)
- 2. Batra Hospital and Medical Research Centre, New Delhi (India)
- 3. Department of Public Health Services, University of Virginia, Charlottesville, VA (United States)
- 4. Department of Neurosurgery, University of Virginia, Charlottesville, VA (United States)
- 5. Department of Cardiology, University of Virginia, Charlottesville, VA (United States)
Description
Aim: To compare the complications and outcomes of Neuroform and Enterprise stents in the treatment of unruptured wide-necked aneurysms. Materials and methods: Under the auspices of the institutional review board, a review of a prospectively collected patient log identified 130 patients who underwent elective stent-assisted coil embolization of a wide-necked aneurysm, including 53 patients treated with an Enterprise stent and 77 patients treated with a Neuroform stent. Immediate and long-term clinical and radiographic outcomes were recorded for all patients. All patient data were handled in accordance with Health Insurance Portability and Accountability Act of 1996 (HIPAA) regulations. Results: The technical success rate was 94%. Overall morbidity was 15% with Enterprise stents and 3% with Neuroform stents (p = 0.020). However, the type of stent used was not predictive of clinical outcomes as measured by the modified Rankin scale. In a multivariate analysis, the use of a Neuroform stent was one of the predictors of retreatment (p = 0.034). Conclusion: Multivariate analyses identified the use of Neuroform stents as an independent predictor of the need for retreatment and the use of Enterprise stents as an independent predictor of morbidity. However, the type of stent was not predictive of clinical outcome as measured by the modified Rankin scale. - Highlights: • The use of Enterprise stents was an independent predictor of morbidity. • The use of Neuroform stents was an independent predictor for retreatment. • The type of stent was not predictive of clinical outcome as measured by the mRS
Availability note (English)
Available from http://dx.doi.org/10.1016/j.crad.2014.07.015Additional details
Identifiers
- DOI
- 10.1016/j.crad.2014.07.015;
- PII
- S0009-9260(14)00377-8;
Publishing Information
- Journal Title
- Clinical Radiology
- Journal Volume
- 69
- Journal Issue
- 12
- Journal Page Range
- p. e471-e476
- ISSN
- 0009-9260
- CODEN
- CLRAAG
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46117494
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLOOD VESSELS; COMPARATIVE EVALUATIONS; DISEASE INCIDENCE; GRAFTS; MULTIVARIATE ANALYSIS; PATIENTS; REVIEWS; VASCULAR DISEASES
- Descriptors DEC
- BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DISEASES; DOCUMENT TYPES; EVALUATION; MATHEMATICS; ORGANS; STATISTICS; TRANSPLANTS
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.