Published January 2010 | Version v1
Journal article

Simulation technique on dose-rate distribution in a 60Co gamma-ray irradiation field

  • 1. Japan Atomic Energy Agency, Takasaki Advanced Radiation Research Inst., Takasaki, Gunma (Japan)

Description

Dose-rate distribution in irradiation field of 60Co gamma-ray was calculated using Monte Carlo photon transport code named as EGS4-SPG code. The dose rate values measured by the ionization chamber and the alanine dosimeter were compared with calculated ones for the evaluation of the validity of the calculation. As a result, the difference between measurements and the calculation value was within ± a few% except for a position very near the source for a wide board radiation source. The dose-rate distribution can be estimated using these numerical results at the beforehand planning of a board radiation source arrangement although dose-rate measurement should be done only for a position very near the radiation source, where calculated value disagreed. The dose rate distribution measurement after the radiation source arrangement enables us to save number of the dosimeter and measurement time. (author)

Availability note (English)

Available from http://dx.doi.org/10.3769/radioisotopes.59.11

Additional details

Identifiers

Publishing Information

Journal Title
Radioisotopes (Tokyo)
Journal Volume
59
Journal Issue
1
Journal Page Range
p. 11-19
ISSN
0033-8303

Optional Information