Published June 1986
| Version v1
Journal article
Dosimetric quantities for 300 KeV neutrons
Description
Dosimetric quantities for 300 KeV neutrons in the ICRU standard tissue sphere were evaluated. The Monte Carlo code NEDEP which performs neutron-photon-charged particles coupled transport was used in the direct estimation of absorbed dose and dose equivalent. Some important quantities calculated are as follows; Deep dose equivalent index HI,d: 1.78x10-11 Sv-cm2 Shallow dose equivalent index HI,s: 2.08x10-11 Sv-cm2 Ambient dose equivalent H*(0.07): 1.7x10-11 Sv-cm2 Ambient dose equivalent H*(10): 1.78x 10-11 Sv-cm2 Effecttive quality factor Q-bar*(10): 12.4 (Author)
Additional details
Publishing Information
- Journal Title
- Radiat. Prot.
- Journal Volume
- 11
- Journal Issue
- 1
- Series
- Radiat. Prot.
- Journal Page Range
- 37-43
- CODEN
- BBHCD
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 18049819
- Subject category
- S73: NUCLEAR PHYSICS AND RADIATION PHYSICS;
- Descriptors DEI
- DOSE EQUIVALENTS; ICRU; KEV RANGE 100-1000; NEUTRONS; QUALITY FACTOR; RADIATION QUALITY
- Descriptors DEC
- BARYONS; ELEMENTARY PARTICLES; ENERGY RANGE; FERMIONS; HADRONS; INTERNATIONAL ORGANIZATIONS; KEV RANGE; NUCLEONS