Published 2008 | Version v1
Book

Hydrogen assessment in PHWR pressure tubes during post irradiation examination

  • 1. Post Irradiation Examination Div., Bhabha Atomic Research Centre, Mumbai (India)

Description

The paper discusses the sampling procedure and technique for estimation of the hydrogen content of the operating pressure tubes as hydrogen equivalent (Heq). It gives the comparison of Heq content in the Zircaloy-2 and Zr-2.5%Nb pressure tubes of PHWRs at different operating periods ranging from 6.7 to 11.45 hot operating years of reactor operation

Part of:
Theme meeting on recent advances in post-irradiation examination: programme and abstracts

Additional details

Publishing Information

Publisher
Indira Gandhi Centre for Atomic Research
Imprint Place
Kalpakkam (India)
Imprint Title
Theme meeting on recent advances in post-irradiation examination: programme and abstracts
Imprint Pagination
81 p.
Journal Page Range
p. 42

Conference

Title
theme meeting on recent advances in post-irradiation examination
Acronym
RAP-2008
Dates
22-24 May 2008
Place
Kalpakkam (India)

Optional Information

Notes
Abstract prepared