Charging system functioning of the Vivitron in voltage testings. New developments

Description

The behaviour of the charging system for the initial commissioning of the Vivitron generator was quite satisfying apart from the excessive parasitic currents at the rollers. That led us to study and test many solutions up to the point that a humidity level higher than thought was discovered as the most probable cause of the problem