Published May 2021 | Version v1
Journal article

Influence of pipe material on biofilm microbial communities found in drinking water supply system

  • 1. Department of Biology and Biotechnology of Microorganisms, Institute of Biological Sciences, The John Paul II Catholic University of Lublin, Konstantynów Street 1 I, 20-708, Lublin (Poland)
  • 2. Institute of Agrophysics, Polish Academy of Sciences, Doświadczalna 4, 20-290, Lublin (Poland)
  • 3. Faculty of Environmental Protection Engineering, Lublin University of Technology, ul. Nadbystrzycka 40B, 20-618, Lublin (Poland)
  • 4. Department of Agricultural Microbiology, Institute of Soil Science and Plant Cultivation–State Research Institute (IUNG-PIB), Czartoryskich Street 8, 24-100, Puławy (Poland)
  • 5. Department of Biochemistry and Environmental Chemistry, The John Paul II Catholic University of Lublin, Konstantynów Street 1 I, 20-708, Lublin (Poland)

Description

The biofilms and water samples from a model installation built of PVC-U, PE-HD and cast iron pipes were investigated using standard heterotrophic plate count and 16S rRNA Next Generation Sequencing. The results of the high throughput identification imply that the construction material strongly influences the microbiome composition. PVC-U and PE-HD pipes were dominated with Proteobacteria (54–60%) while the cast pipe was overgrown by Nitrospirae (64%). It was deduced that the plastic pipes create a more convenient environment for the potentially pathogenic taxa than the cast iron. The 7-year old biofilms were described as complex habitats with sharp oxidation-reduction gradients, where co-existence of methanogenic and methanotrophic microbiota takes place. Furthermore, it was found that the drinking water distribution systems (DWDS) are a useful tool for studying the ecology of rare bacterial phyla. New ecophysiological aspects were described for Aquihabitans, Thermogutta and Vampirovibrio. The discrepancy between identity of HPC-derived bacteria and NGS-revealed composition of biofilm and water microbiomes point to the need of introducing new diagnostical protocols to enable proper assessment of the drinking water safety, especially in DWDSs operating without disinfection.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.envres.2020.110433

Additional details

Identifiers

DOI
10.1016/j.envres.2020.110433;
PII
S001393512031330X;

Publishing Information

Journal Title
Environmental Research
Journal Volume
196
Journal Page Range
vp.
ISSN
0013-9351
CODEN
ENVRAL

Optional Information

Copyright
Copyright (c) 2020 Elsevier Inc. All rights reserved.