Published January 1980 | Version v1
Journal article

Environmental gamma dosimetry using CaSO4:Dy TL dosimeters

  • 1. Bhabha Atomic Research Centre, Bombay (India). Div. of Radiological Protection

Description

An account and results of the Indian participation in the international intercomparison of environmental dosimeters held in U.S.A. in 1976, 1977 and 1979 are presented. The intercomparison included field, laboratory and control dosimeters. CaSO4:Dy Teflon TLD disc dosimeters fabricated in India were sent for the experiments of intercomparison. Results showed an excellent agreement between the exposures measured by the above Indian dosimeters, the mean of the measured values of all the dosimeters from different countries and those obtained by organisers of the intercomparison experiments. (M.G.B.)

Additional details

Publishing Information

Journal Title
Bull. Radiat. Prot.
Journal Volume
3
Journal Issue
1-2
Series
Bull. Radiat. Prot.
Journal Page Range
35-39

Conference

Title
7. Indian Association for Radiation Protection conference on radiation environment in life and earth sciences.
Dates
25 - 27 Feb 1980.
Place
Baroda, India.

Optional Information

Notes
4 figures.