Description

In reactor pressure vessels, brittle fracture in case of LOCA must be excluded, i.e. any crack must be arrested within 3/4 of the wall thickness, and crack propagation must be prevented. The safety calculations for this case were updated in consideration of new findings and new technical regulations. The test procedure and the results are reported

Abstract (German)

Fuer Reaktordruckbehaelter ist fuer Kuehlmittelverluststoerfaelle (KMV) ein Sproedbruch auszuschliessen. Dazu muss der Rissarrest innerhalb 3/4 der Wanddicke oder der Ausschluss von Rissspruengen durch Ausschluss der Risseinleitung nachgewiesen werden. Der Sproedbruchsicherheitsnachweis eines Reaktordruckbehaelters fuer die KMV-Stoerfaelle war unter Beruecksichtigung eines neueren Kenntnisstandes und des geaenderten Regelwerks zu aktualisieren. Die Nachweisfuehrung und die Ergebnisse werden berichtet. (orig.)
Part of:
28. MPA seminar: Safety and reliability in energy technology. MPA-NIMS-workshop 'Modern 9-12% Cr-steels for power plant application'. Papers. Vol. 1 and 2

Additional details

Additional titles

Original title (German)
Sproedbruchsicherheitsnachweis eines RDB fuer Kuehlmittelverluststoerfaelle mit Beruecksichtigung der Spannungsmehrachsigkeit

Publishing Information

Imprint Title
28. MPA seminar: Safety and reliability in energy technology. MPA-NIMS-workshop 'Modern 9-12% Cr-steels for power plant application'. Papers. Vol. 1 and 2
Imprint Pagination
[vp.]
Journal Page Range
p. 12.1-12.17
ISSN
0722-401X

Conference

Title
Safety and availability in energy engineering, and MPA-NIMS Workshop: Modern 9-12% Cr steels for power plants
Original Conference Title
28. MPA-Seminar: Sicherheit und Verfuegbarkeit in der Energietechnik, in Verbindung mit dem MPA-NIMS-Workshop: Moderne 9-12% Cr-Staehle fuer Kraftwerke
Acronym
28. MPA seminar
Dates
10-11 Oct 2002
Place
Stuttgart (Germany)

Optional Information

Notes
Imprint:Published in 2 volumes;28. MPA-Seminar: Sicherheit und Verfuegbarkeit in der Energietechnik. MPA-NIMS-Workshop 'Modern 9-12% Cr-steels for power plant application'. Vortraege. Bd. 1 und 2