Published 1981
| Version v1
Report
Restricted
TMI-2 instrument analysis results
Description
The Three Mile Island, Unit 2, accident represents a unique opportunity to examine electrical equipment from an operating power plant involved in a loss-of-coolant-accident (LOCA). Over the past months several instruments have been removed from the containment building middle and upper operating levels for dissection and failure analysis. To date, two area radiation detectors, two loose parts monitoring system charge amplifiers, a source range neutron detector preamplifier and a short length of instrument cable have been examined. Interestingly, even though none of the instruments examined thus far were classified as Class 1E equipment, each was needed and used during and after the accident to monitor plant conditions, and each failed
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 12 p.
- Report number
- SAND--81-1736C
Conference
- Title
- ANS winter meeting.
- Dates
- 29 Nov - 4 Dec 1981.
- Place
- San Francisco, CA, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13664779
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AMPLIFIERS; ELECTRIC CABLES; FAILURES; LOOSE PARTS MONITORING; LOSS OF COOLANT; NEUTRON DETECTORS; REACTOR INSTRUMENTATION; THREE MILE ISLAND-2 REACTOR
- Descriptors DEC
- ACCIDENTS; CABLES; CONDUCTOR DEVICES; ELECTRICAL EQUIPMENT; ENRICHED URANIUM REACTORS; MEASURING INSTRUMENTS; MONITORING; POWER REACTORS; PWR TYPE REACTORS; RADIATION DETECTORS; REACTOR ACCIDENTS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-811103--18.