Published February 1988 | Version v1
Journal article

The effective removal method of copper and cyanide in waste water of metal plating factories

  • 1. Hanyang Univ., Seoul (Republic of Korea)

Description

To investigate the effective removal method of cooper and cyanide compounds in metal plating waste water, removal ratio of cooper and cyanide compounds in solution are measured with varying pH, concentration and contact time. As results of the present experiment, cyanide compounds in the solution are removed to 0.03mg/l or less with 5% NaOCl solution. The present result is satisfied to environmental disposal standards. The removal ratio against pH values show 99% over pH8. As results of neutral precipitation method, copper including solution are removed to 99% at pH8 in short time. The removal ratios of cyanide mixed copper solution against pH values show high efficiency(over 95%) at pH8 and 11 and removal ratios are decreased at pH10.(Author)

Additional details

Publishing Information

Journal Title
Bulletin of Environmental Sciences, Hanyang University
Journal Volume
9
Series
Bull. Environ. Sci., Hanyang Univ.
Journal Page Range
5-11
CODEN
HKROD

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
20018341
Subject category
S58: GEOSCIENCES; S38: RADIATION CHEMISTRY, RADIOCHEMISTRY AND NUCLEAR CHEMISTRY;
Descriptors DEI
COPPER COMPOUNDS; CYANIDES; PRECIPITATION; PURIFICATION; WASTE WATER
Descriptors DEC
HYDROGEN COMPOUNDS; LIQUID WASTES; OXYGEN COMPOUNDS; POLAR SOLVENTS; SEPARATION PROCESSES; SOLVENTS; TRANSITION ELEMENT COMPOUNDS; WASTES; WATER