Published March 1996 | Version v1
Report

Protection against dynamic phenomena induced by a postulated rupture of the pipe from SG 6 on the +14.7 m floor

Description

Prepared within the project of ''Primary and secondary piping integrity assessment at the Dukovany NPP'' which is aimed at refining the assessment of the initiating event probability and proneness of the piping to a postulated whipping, the report analyses the piping leading from steam generator 2 with respect to a postulated rupture. The analysis was based on ANSI/ANS 58.2 and on the 0.1 A0 approach as specified by the RSK Leitlinien. Practical recommendations were derived from the analysis

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic.

Additional details

Additional titles

Original title (Czech)
Ochrana proti dynamickym jevum vyvolanym postulovanym roztrzenim potrubi od PG 6 na podlazi +14,7 m
Augmented title (English)
Dukovany NPP

Publishing Information

Imprint Pagination
20 p.
Report number
UJV--10633-T

Optional Information

Notes
5 tabs., 6 figs., 6 refs.