Temporal distribution of the H atom and H2 densities in a pulsed microwave hydrogen plasmas has been measured simultaneously by two-photon absorption laser-induced fluorescence (TALIF). The measurement of the H-atom absolute density obtained by NO2 titration in a flow tube reactor shows that the density of H2 could be determined by the measured effective lifetime of the TALIF signal via the quenching equation. The H-atom density of about 1.5 x 1015 cm-3 in both pulsed and stationary phases does not obviously change. It is found that the gas temperature volume effect plays an important role in governing the distributions of the H-atom density and it is mole fraction. The calculated gas temperature is in good consistent with the rotational temperature of H2 measured by optical emission spectroscopy in pulsed phase

Additional details

Publishing Information

Journal Title
Chinese Physics Letters
Journal Volume
20
Journal Issue
4
Journal Page Range
p. 489-492