A dosimetry study comparing NCS report-2, IAEA TRS-381, AAPM TG-51 and IAEA TRS-398 for high energy photon beams

  • 1. Radiotherapy , Nuclear Medicine Department, National Cancer Institute, Cairo University, Cairo (Egypt)
  • 2. Biophysics Department, Faculty of Science, Cairo University, Cairo (Egypt)
  • 3. National Institute of Standards (Egypt)

Description

In the last 5 years the American Association of Physicists in Medicine Task group 51 (AAPM TG-51) and the International Atomic Energy Agency (IAEA) published a new high-energy photon and electron dosimetry protocol. These protocols are based on the use of an ion chamber having an absorbed-dose to water calibration factor. These are different from the previous NCS report-2 and IAEA TRS-277 protocols, which require air kerma calibration factor, the aim of this study is to present the dose comparison between various dosimetry protocols and the IAEA TRS-398 protocol for clinical reference dosimetry of high energy photon beams. The absorbed-dose to water measured according to the NCS Report-2, International Atomic Energy Agency technical Report Series No. 277 (IAEA TRS-277) and, TG-51 are compared to that measured using the TRS-398 protocol. This study shows that the absorbed dose which is measured with The IAEA TRS-398 formalisms is higher than that calculated with NCS Report-2 and IAEA TRS-277 formalisms within range from 0.4 to 1.3% and from 0.7 to 2.1% respectively for different higher energy photon beams of Co-60, 6, 8 and 18 MV. as sensed by different ionization chambers, The chambers used are PTW 30001, 30004, and NE-2571; which have calibration factors NK and ND,W traceable to the Bureau International des Poids et Measures (BIPM). In contrast, the absorbed-dose to water measured according to TG-51 is in good agreement with TRS-398 within about 0.3% for photon beams

Files

38092983.pdf

Files (217.0 kB)

Name Size Download all
md5:c8234d483e3b0710284b4fd43cdde4b8
217.0 kB Preview Download
Part of:
Proceedings of the Eigth Radiation Physics and Protection Conference (RPC-2006)

Additional details

Publishing Information

Imprint Title
Proceedings of the Eigth Radiation Physics and Protection Conference (RPC-2006)
Imprint Pagination
478 p.
Journal Page Range
p. 333-345
Report number
INIS-EG--192

Conference

Title
8. Radiation Physics and Protection Conference
Acronym
RPC-2006
Dates
12-15 Nov 2006
Place
Beni Sueif (Egypt)

Optional Information

Notes
Imprint:Available Submitted to the Arab Journal of Nuclear Sciences and Applications, ISSN 1110-0451, CODEN: AJNADV, Special Issue, Vol. 40, Jun 2007