Operational specifications of the laser illuminated track etch scattering dosemeter reader

  • 1. Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)
  • 2. Dept. Nuclear Engineering, Univ. of Missouri-Rolla, Rolla, MO 65409 (United States)

Description

The personnel dosimetry operations team at the Los Alamos National Laboratory (LANL) has accepted the laser illuminated track etch scattering (LITES) dosemeter reader into its suite of radiation dose measurement instruments. The LITES instrument transmits coherent light from a He-Ne laser through the pertinent track etch foil and a photodiode measures the amount of light scattered by the etched tracks. A small beam stop blocks the main laser light, while a lens refocuses the scattered light into the photodiode. Three stepper motors in the current LITES system are used to position a carousel that holds 36 track etch dosemeters (TEDs). Preliminary work with the LITES system demonstrated the device had a linear response in counting foils subjected to exposures up to 50 mSv (5.0 rem). The United States Dept. of Energy requires that the annual general employee dose not exceed 50 mSv (5.0 rem). On a regular basis, LANL uses the Autoscan-60 reader system (Thermo Electron Corp.) for counting track etch dosemeters. However, LANL uses a 15 h etch process for CR-39 dosemeters, and this produces more and larger track etch pits than the 6 h etch used by many institutions. Therefore, LANL only uses the Autoscan-60 for measuring neutron dose equivalent up to exposure levels of ∼3 mSv (300 mrem). The LITES system has a measured lower limit of detection of ∼0.6 mSv (60 mrem), and it has a correlation coefficient of R 2 = 0.99 over an exposure range up to 500 mSv (50.0 rem). A series of blind studies were done using three methods: the Autoscan-60 system, manual counting by optical microscope and the LITES instrument. A collection of track etch dosemeters of unknown neutron dose equivalent (NDE) were analysed using the three methods, and the performance coefficient (PC) was calculated when the NDE became known. The Autoscan-60 and optical microscope methods had a combined PC = 0.171, and the LITES instrument had a PC = 0.194, where a PC less than or equal to 0.300 is considered satisfactory. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncj004

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
120
Journal Issue
1-4
Journal Page Range
p. 466-469
ISSN
0144-8420

Conference

Title
14. International Conference on Solid State Dosimetry
Acronym
SSD14
Dates
27 Jun - 2 Jul 2004
Place
New Haven (United States)

Optional Information

Notes
6 refs