Operational specifications of the laser illuminated track etch scattering dosemeter reader
- 1. Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)
- 2. Dept. Nuclear Engineering, Univ. of Missouri-Rolla, Rolla, MO 65409 (United States)
Description
The personnel dosimetry operations team at the Los Alamos National Laboratory (LANL) has accepted the laser illuminated track etch scattering (LITES) dosemeter reader into its suite of radiation dose measurement instruments. The LITES instrument transmits coherent light from a He-Ne laser through the pertinent track etch foil and a photodiode measures the amount of light scattered by the etched tracks. A small beam stop blocks the main laser light, while a lens refocuses the scattered light into the photodiode. Three stepper motors in the current LITES system are used to position a carousel that holds 36 track etch dosemeters (TEDs). Preliminary work with the LITES system demonstrated the device had a linear response in counting foils subjected to exposures up to 50 mSv (5.0 rem). The United States Dept. of Energy requires that the annual general employee dose not exceed 50 mSv (5.0 rem). On a regular basis, LANL uses the Autoscan-60 reader system (Thermo Electron Corp.) for counting track etch dosemeters. However, LANL uses a 15 h etch process for CR-39 dosemeters, and this produces more and larger track etch pits than the 6 h etch used by many institutions. Therefore, LANL only uses the Autoscan-60 for measuring neutron dose equivalent up to exposure levels of ∼3 mSv (300 mrem). The LITES system has a measured lower limit of detection of ∼0.6 mSv (60 mrem), and it has a correlation coefficient of R 2 = 0.99 over an exposure range up to 500 mSv (50.0 rem). A series of blind studies were done using three methods: the Autoscan-60 system, manual counting by optical microscope and the LITES instrument. A collection of track etch dosemeters of unknown neutron dose equivalent (NDE) were analysed using the three methods, and the performance coefficient (PC) was calculated when the NDE became known. The Autoscan-60 and optical microscope methods had a combined PC = 0.171, and the LITES instrument had a PC = 0.194, where a PC less than or equal to 0.300 is considered satisfactory. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncj004Additional details
Identifiers
- DOI
- 10.1093/rpd/ncj004;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 120
- Journal Issue
- 1-4
- Journal Page Range
- p. 466-469
- ISSN
- 0144-8420
Conference
- Title
- 14. International Conference on Solid State Dosimetry
- Acronym
- SSD14
- Dates
- 27 Jun - 2 Jul 2004
- Place
- New Haven (United States)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 44021963
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOSE EQUIVALENTS; DOSE-RESPONSE RELATIONSHIPS; HELIUM-NEON LASERS; LANL; MANUALS; NEUTRONS; PARTICLE TRACKS; PERSONNEL DOSIMETRY; RADIATION DOSES; RADIATION PROTECTION; SENSITIVITY; SPECIFICATIONS; THERMOLUMINESCENT DOSEMETERS; THERMOLUMINESCENT DOSIMETRY
- Descriptors DEC
- BARYONS; DOCUMENT TYPES; DOSEMETERS; DOSES; DOSIMETRY; ELEMENTARY PARTICLES; FERMIONS; GAS LASERS; HADRONS; LASERS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; NATIONAL ORGANIZATIONS; NUCLEONS; US DOE; US ORGANIZATIONS
Optional Information
- Notes
- 6 refs