A surface loop array for in vivo small animal MRI/fMRI on 7T human scanners
- 1. Interdisciplinary Institute of Neuroscience and Technology, Key Laboratory for Biomedical Engineering of Ministry of Education, Qiushi Academy for Advanced Studies, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou (China)
- 2. Department of Neurosurgery, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou (China)
Description
Small animals such as non-human primate (NHP) and rodent are valuable models in frontier neuroscience researches, and comparative research between the animal model and human is helpful to understand and reveal the functional brain circuits in cognition and underlying mechanism in psychological disease. Small animals can be trained or anesthetized to endure long-term and multiple imaging scans; however, the concomitant needs in subcortical structure and function investigations pose major challenges in, e.g. spatial resolution, scan time efficiency, spatial/temporal signal-to-noise-ratio, as well as apparatus mechanical fixation. In addition, comparative investigations across species are also expected to be conducted under similar physical environment (such as the main magnetic field strength, RF pulse shape, sequence protocols, gradient waveform, system stability, etc in MRI), in order to avoid possible deviation in signal detection under different platforms, as well as to reduce experiment complexity. We have proposed a novel 5-channel surface coil that is equipped on 7T human MRI scanners and designed for small animal structural and functional MRI. Through a series of in vivo experiments over an anesthetized rat and macaque, the presented coil shows its main characteristics in, i.e. flexible coil mounting, reduced FOV, high temporal SNR, and parallel imaging capability. Such design is able to compensate the relatively lower gradient slew rate of human scanners versus those with smaller bores, and thus effectively facilitates in vivo microscopic structural MR images being obtained within a shortened and safe period of anesthesia; besides, it also enables high-resolution functional MRI (i.e. spin-echo based) being achieved with reasonable temporal resolution, distortion level and functional contrast. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1361-6560/aaf9e4Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 64
- Journal Issue
- 3
- Journal Page Range
- [9 p.]
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52003658
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- IN VIVO; MAGNETIC FIELDS; NMR IMAGING; PULSE SHAPERS; RATS; SIGNAL-TO-NOISE RATIO; SPATIAL RESOLUTION; SPIN ECHO
- Descriptors DEC
- ANIMALS; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; ELECTRONIC CIRCUITS; MAMMALS; PULSE CIRCUITS; RESOLUTION; RODENTS; SIGNAL CONDITIONERS; VERTEBRATES