Evaluation of pipeline leak detection systems

  • 1. Midwest Research Inst., Kansas City, MO (United States)

Description

Leaking underground storage tank system presents an environmental concern and a potential health hazard. It is well known that leaks in the piping associated with these systems account for a sizeable fraction of the leaks. EPA has established performance standards for pipeline leak detection systems, and published a document presenting test protocols for evaluating these systems against the standards. This paper discusses a number of facets and important features of evaluating such systems, and presents results from tests of several systems. The importance of temperature differences between the ground and the product in the line is shown both in theory and with test data. The impact of the amount of soil moisture present is addressed, along with the effect of frozen soil. These features are addressed both for line tightness test systems, which must detect leaks of 0.10 gal/h (0.38 L/h) at 150% of normal line pressure, or 0.20 gal/h (0.76 L/h) at normal line pressure, and for automatic line leak detectors that must detect leaks of 3 gal/h (11 L/h) at 10 psi (69 kPa) within an hour of the occurrence of the leak. This paper also addresses some statistical aspects of the evaluation of these systems. Reasons for keeping the evaluation process ''blind'' to the evaluated company are given, along with methods for assuring that the tests are blind. Most importantly, a test procedure is presented for evaluating systems that report a flow rate (not just a pass/fail decision) that is much more efficient than the procedure presented in the EPA protocol, and is just as stringent

Part of:
Leak detection for underground storage tanks

Additional details

Publishing Information

Publisher
American Society for Testing and Materials.
Imprint Place
Philadelphia, PA (United States)
ISBN
0-8031-1858-9
Imprint Title
Leak detection for underground storage tanks
Imprint Pagination
241 p.
Journal Page Range
p. 151-161.

Conference

Title
Symposium on leak detection for underground storage tanks.
Dates
29 Jan 1992.
Place
New Orleans, LA (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
25014790
Subject category
S02: PETROLEUM;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CONTAMINATION; ENVIRONMENTAL EFFECTS; LEAK TESTING; LEAKS; PETROLEUM PRODUCTS; PIPELINES; SOILS; UNDERGROUND STORAGE
Descriptors DEC
STORAGE; TESTING

Optional Information

Secondary number(s)
CONF-9201163--.