Published June 2016 | Version v1
Journal article

Radiation protection cabin for catheter-directed liver interventions: operator dose assessment

  • 1. Department of Radiology, KU/UZLeuven, Herestraat 49, 3000 Leuven (Belgium)
  • 2. Internal Prevention Service, Radiation Protection and Dosimetry, UZLeuven, Herestraat 49, 3000 Leuven (Belgium)
  • 3. Department of Experimental Radiotherapy, KULeuven, Herestraat 49, 3000 Leuven (Belgium)

Description

The number and complexity of interventional radiological procedures and in particular catheter-directed liver interventions have increased substantially. The current study investigates the reduction of personal doses when using a dedicated radiation protection cabin (RPC) for these procedures. Operator and assistant doses were assessed for 3 series of 20 chemo-infusion/chemoembolisation interventions, including an equal number of procedures with and without RPC. Whole body doses, finger doses and doses at the level of knees and eyes were evaluated with different types of TLD-100 Harshaw dosemeters. Dosemeters were also attached on the three walls of the RPC. The operator doses were significantly reduced by the RPC, but also without RPC, the doses appear to be limited as a result of thorough optimisation with existing radiation protection tools. The added value of the RPC should thus be determined by the outcome of balancing dose reduction and other aspects such as ergonomic benefits. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncv438

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
170
Journal Issue
1-4
Journal Page Range
p. 274-278
ISSN
0144-8420

Conference

Title
5. International Conference on Individual Monitoring of Ionising Radiation
Acronym
IM2015
Dates
20-24 Apr 2015
Place
Bruges (Belgium)

Optional Information

Notes
4 refs.