Published April 1984 | Version v1
Report Restricted

TMI-2 in-core instrument damage - an update. Volume II

Description

Additional in situ tests were performed during July and August 1983 on the in-core instruments located in TMI Unit 2. These tests were intended to reduce the uncertainty associated with early test data and better define the extent of damage in the reactor vessel. The condition of the self-powered neutron detectors and the location of newly formed thermocouple junctions suggests the possibility that significant damage occurred in the central area of the lower reactor vessel. The extension cables associated with the in-core instruments appeared to be in generally good condition

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A05/MF A01; 1 as DE84015257.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
78 p.
Report number
GEND-INF--031-Vol.2