Published October 1996 | Version v1
Journal article

Anomalies in hepatobiliary excretion of Technetium-99m-MAG3 preparations

Description

Technetium-99m-MAG3 is accepted as a renal tubular function agent. However, sporadic liver and gall bladder visualisation during its clinical use is clearly a disadvantage. HPLC-purified 99mTc-MAG3 samples exhibited appreciable hepatobiliary uptake (7%), and an elevated level of such uptake was observed in unpurified kit preparations, which was stated to be associated with the excretory property of the radiolabeled kit impurities. To verify this we attempted to quantitate the hepatobiliary uptake of the kit preparations with that of its radiolabeled components. The contribution of each component toward hepatobiliary uptake of the sample was calculated from their abundance in the chelate mixture and the individual biodistribution of the isolated components. However, the anticipated hepatobiliary uptake of different preparations of 99mTc-MAG3 calculated in this way was always lower than that of the experimental value determined directly. Further work is needed to explain the anomaly

Additional details

Identifiers

PII
S0969805196001163;

Publishing Information

Journal Title
Nuclear Medicine and Biology
Journal Volume
23
Journal Issue
7
Journal Page Range
p. 867-872
ISSN
0969-8051
CODEN
NMBIEO

Optional Information

Copyright
Copyright (c) 1996 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.