Calorimetric power measurements in the EAST ECRH system

  • 1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

Description

In this paper, the measurement method of calorimetric power for an electron cyclotron resonance heating (ECRH) system for EAST is presented. This method requires measurements of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature stability is controlled to obtain more accurate results. The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. Also, a novel temperature calibration method is proposed. This kind of calibration method is accurate and effective, and can be easily implemented. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/2058-6272/aa7ec9

Additional details

Identifiers

Publishing Information

Journal Title
Plasma Science and Technology
Journal Volume
19
Journal Issue
10
Journal Page Range
[12 p.]
ISSN
1009-0630

INIS

Country of Publication
China
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49070173
Subject category
S42: ENGINEERING; S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
CALIBRATION; CALORIMETRY; COOLING; ECR HEATING; FLUID FLOW; HT-7U TOKAMAK; WATER