Neutron tomography using projection data obtained by Monte Carlo simulation for nondestructive evaluation
Creators
- 1. Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Prgrama de Engenharia Nuclear
Description
This work present the application of a computer package for generating of projection data for neutron computerized tomography, and in second part, discusses an application of neutron tomography, using the projection data obtained by Monte Carlo technique, for the detection and localization of light materials such as those containing hydrogen, concealed by heavy materials such as iron and lead. For tomographic reconstructions of the samples simulated use was made of only six equal projection angles distributed between 0 deg C and 180 deg C, with reconstruction making use of an algorithm (ARIEM), based on the principle of maximum entropy. With the neutron tomography it was possible to detect and locate polyethylene and water hidden by lead and iron (with 1 cm-thick). Thus, it is demonstrated that thermal neutrons tomography is a viable test method which can provide important interior information about test components, so, extremely useful in routine industrial applications.(author)
Additional details
Publishing Information
- Journal Title
- Revista Brasileira de Ciencias Mecanicas
- Journal Volume
- 24
- Journal Issue
- 4
- Journal Page Range
- p. 309-311
- ISSN
- 0100-7386
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 36090822
- Subject category
- S36: MATERIALS SCIENCE;
- Descriptors DEI
- ALGORITHMS; COMPUTER CODES; COMPUTERIZED TOMOGRAPHY; INSPECTION; IRON; LEAD; MATERIALS TESTING; NEUTRON DIFFRACTION; NEUTRON RADIOGRAPHY; POLYETHYLENES; TOMOGRAPHY
- Descriptors DEC
- COHERENT SCATTERING; DIAGNOSTIC TECHNIQUES; DIFFRACTION; ELEMENTS; INDUSTRIAL RADIOGRAPHY; MATERIALS TESTING; MATHEMATICAL LOGIC; METALS; NONDESTRUCTIVE TESTING; ORGANIC COMPOUNDS; ORGANIC POLYMERS; POLYMERS; POLYOLEFINS; SCATTERING; TESTING; TOMOGRAPHY; TRANSITION ELEMENTS
Optional Information
- Notes
- 9 refs., 4 figs. Also available from http://www.scielo.br/scielo.php?script=sci_arttext&pidS0100-73862002000400009 &lngen&nrmiso&tlngen