Published 1990
| Version v1
Miscellaneous
Two-phase pressure drop and wall-temperature measurements at steady state in the high-pressure, nucleate and film-boiling regimes
Creators
- 1. Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.
Description
Measurements of critical heat flux, post-dryout pressure drops and wall temperatures have been obtained using two circular tubes of different inside diameters. The test sections were constructed with Inconel-600 tubes and electrically heated with direct current. They were positioned vertically and cooled with an upward flow of light water. Six pressure taps and 15 thermocouples were installed along various axial locations. The tests covered pressures of 5000, 7000 and 9600 kPa, mass flux of 1000 to 10000 kg.m-2.s-1, and inlet quality of -20 to -1%. This paper presents some observations and preliminary results obtained from the experiment. (Author) 3 refs., 5 figs., tab
Additional details
Publishing Information
- Imprint Title
- Proceedings of the 11th Annual Conference of the Canadian Nuclear Society
- Imprint Pagination
- 440 p.
- Journal Page Range
- p. 12.19-12.21.
- Report number
- INIS-mf--13847
Conference
- Title
- Canadian Nuclear Society 11. annual conference.
- Dates
- 3-6 Jun 1990.
- Place
- Toronto, ON (Canada).
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 25031369
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- CRITICAL HEAT FLUX; DRYOUT; EXPERIMENTAL DATA; FILM BOILING; MEDIUM PRESSURE; NUCLEATE BOILING; PRESSURE DROP; TEMPERATURE DISTRIBUTION; TWO-PHASE FLOW
- Descriptors DEC
- BOILING; DATA; FLUID FLOW; HEAT FLUX; INFORMATION; NUMERICAL DATA; PHASE TRANSFORMATIONS