Two-phase pressure drop and wall-temperature measurements at steady state in the high-pressure, nucleate and film-boiling regimes

  • 1. Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.

Description

Measurements of critical heat flux, post-dryout pressure drops and wall temperatures have been obtained using two circular tubes of different inside diameters. The test sections were constructed with Inconel-600 tubes and electrically heated with direct current. They were positioned vertically and cooled with an upward flow of light water. Six pressure taps and 15 thermocouples were installed along various axial locations. The tests covered pressures of 5000, 7000 and 9600 kPa, mass flux of 1000 to 10000 kg.m-2.s-1, and inlet quality of -20 to -1%. This paper presents some observations and preliminary results obtained from the experiment. (Author) 3 refs., 5 figs., tab

Part of:
Proceedings of the 11th Annual Conference of the Canadian Nuclear Society

Additional details

Publishing Information

Imprint Title
Proceedings of the 11th Annual Conference of the Canadian Nuclear Society
Imprint Pagination
440 p.
Journal Page Range
p. 12.19-12.21.
Report number
INIS-mf--13847

Conference

Title
Canadian Nuclear Society 11. annual conference.
Dates
3-6 Jun 1990.
Place
Toronto, ON (Canada).

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
25031369
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference, Numerical Data
Descriptors DEI
CRITICAL HEAT FLUX; DRYOUT; EXPERIMENTAL DATA; FILM BOILING; MEDIUM PRESSURE; NUCLEATE BOILING; PRESSURE DROP; TEMPERATURE DISTRIBUTION; TWO-PHASE FLOW
Descriptors DEC
BOILING; DATA; FLUID FLOW; HEAT FLUX; INFORMATION; NUMERICAL DATA; PHASE TRANSFORMATIONS