Published 1996 | Version v1
Journal article

High volume air samplers: A valuable tool to determine radionuclide concentrations

  • 1. PTI Physik - Technik - Innovation, Erlangen (Germany)
  • 2. FCI Frenzel Consulting and Instruments, Straubenhardt (Germany)

Description

It is not only the discussion on the atomic test ban treaty (CTBT) which requires low level measuring technique for aerosolbound radionuclides in the air in the order of magnitude of μBq/m3. For the understanding of transport mechanisms of the radionuclides in the air this technique is essential as well. The capability of the low level measuring technique with high volume samplers is described in this paper, using some results of Deutscher Wetterdienst (DWD) and Physikalisch-Technische Bundesanstalt (PTB). (orig.)

Abstract (German)

Nicht nur durch die gegenwaertigen Verhandlungen und Diskussionen im Gefolge der Konferenz um den Atomwaffenteststopp (CTBT) sind Messmethoden fuer niedrigste Aktivitaetskonzentrationen (∝μBq/m3) hochaktuell. Durch Vergleich und Korrelation z.B. mit meteorologischen Parametern koennen wichtige Erkenntnisse fuer die Transportmechanismen von Radionukliden in der Luft gewonnen werden. Die Leistungsfaehigkeit dieser 'Low-Level'-Messtechnik mit 'High Volume Samplers' wird hier beschrieben, u.a. anhand von Beispielen des Deutschen Wetterdienstes (DWD) und der Physikalisch-Technischen Bundesanstalt (PTB). (orig.)

Additional details

Publishing Information

Journal Title
StrahlenschutzPraxis (Koeln)
Journal Volume
2
Journal Issue
4
Journal Page Range
p. 83-87.
ISSN
0947-434X
CODEN
STPRFM