Qualification Tests for the New Air Sampling System at the 296-Z-1 Stack
Description
This report documents tests performed by Pacific Northwest National Laboratory to verify that the new air monitoring system for the 296-Z-1 ventilation exhaust stack meets the applicable regulatory criteria regarding the placement of the air sampling probe, sample transport, and stack flow measurement accuracy. These criteria ensure that the contaminants in the stack are well mixed with the airflow at the location of the probe so that the collected sample represents the whole. The sequence of tests addresses the acceptability of the flow angle relative to the probe uniformity of air velocity and gaseous and particle tracers in the cross section of the stack delivery of the sample from the sampler nozzle to the collection filter. The tests conducted on the air monitoring system demonstrated that the location for the air-sampling probe meets all performance criteria for air sampling systems at nuclear facilities. The performance criterion for particle transport was also met. All tests were successful, and all acceptance criteria were met
Availability note (English)
Available from PURL: https://www.osti.gov/servlets/purl/15010055-HMIvzv/native/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- [vp.]
- Report number
- PNNL--14057
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 36026654
- Subject category
- S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- ACCURACY; AIR; CROSS SECTIONS; MONITORING; NOZZLES; NUCLEAR FACILITIES; PERFORMANCE; PROBES; SAMPLERS; SAMPLING; TRANSPORT; VELOCITY; VENTILATION
- Descriptors DEC
- EQUIPMENT; FLUIDS; GASES
Optional Information
- Contract/Grant/Project number
- 820201000; AC06-76RL01830
- Funding organization
- US Department of Energy (United States)