Published March 2014 | Version v1
Journal article

Impact of a new respiratory amplitude-based gating technique in evaluation of upper abdominal PET lesions

  • 1. Department of Nuclear Medicine, Centre Hospitalier Princesse Grace, Monaco (Monaco)
  • 2. Department of Medical Physics, Centre Hospitalier Princesse Grace, Monaco (Monaco)

Description

PET acquisition requires several minutes which can lead to respiratory motion blurring, to increase partial volume effect and SUV under-estimation. To avoid these artifacts, conventional 10-min phase-based respiratory gating (PBRG) can be performed but is time-consuming and difficult with a non-compliant patient. We evaluated an automatic amplitude-based gating method (AABG) which keeps 35% of the counts at the end of expiration to minimize respiratory motion. We estimated the impact of AABG on upper abdominal lesion detectability, quantification and patient management. Methods: We consecutively included 31 patients (82 hepatic and 25 perihepatic known lesions). Each patient underwent 3 acquisitions on a Siemens Biograph mCT (4 rings and time-of-flight): a standard free-breathing whole-body (SWB, 5–7 steps/2.5 min per step, 3.3 ± 0.4 MBq/kg of 18F-FDG), a 10-min PBRG with six bins and a 5-min AABG method. All gated acquisitions were performed with an ANZAI respiratory gating system. SUVmax and target to background ratio (TBR, defined as the maximum SUV of the lesion divided by the mean SUV of a region of interest drawn in healthy liver) were compared. Results: All 94 lesions in SWB images were detected in the gated images. 10-min PBRG and 5-min AABG acquisitions respectively revealed 9 and 13 new lesions and relocated 7 and 8 lesions. Four lesions revealed by 5-min AABG were missed by 10-min PBRG in 3 non-compliant patients. Both gated methods failed to relocate 2 lesions seen on SWB acquisition. Compared to SWB, TBR increased significantly with 10-min PBRG and with 5-min AABG (respectively 41 ± 59%, p = 4.10–3 and 66 ± 75%, p = 6.10–5) whereas SUVmax did not (respectively 14 ± 43%, p = 0.29 with 10-min PBRG, and 24 ± 46%, p = 0.11 with 5-min AABG). Conclusion: The AABG is a fast and a user-friendly respiratory gating method to increase detectability and quantification of upper abdominal lesions compared to the conventional PBRG procedure and the SWB acquisition

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2013.11.010

Additional details

Identifiers

DOI
10.1016/j.ejrad.2013.11.010;
PII
S0720-048X(13)00600-1;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
83
Journal Issue
3
Journal Page Range
p. 509-515
ISSN
0720-048X
CODEN
EJRADR

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47005279
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
AMPLITUDES; COMPARATIVE EVALUATIONS; IMAGES; LIVER; PATIENTS; POSITRON COMPUTED TOMOGRAPHY; RESPIRATION
Descriptors DEC
BODY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; EMISSION COMPUTED TOMOGRAPHY; EVALUATION; GLANDS; ORGANS; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.