Published 1988
| Version v1
Report
Open
Reactimeter with analogue and pulse channels for reactor power measurements
Description
The reactor power meter is described, operating in tendecade range of the reactor power change. The reactimeter pulse channel, using the directly connected neutron flux detector CHM-at the entrance and the charge sensitive preamplifier with high input dynamic capacitance allowed to uncrease its sensitivity and provided the measurement at the lower power levels. It had increased the nuclear safety of the first physical reactor start-ups and had reduced its performance time. The instrument testing had indicated the high sensitivity and noise impurity of the reactimeter pulse channel. 6 refs.; 4 figs
Availability note (English)
MF available from INIS under the Report Number.Files
23048938.pdf
Files
(399.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:696a0c9a50741b53885b8593f261b98f
|
399.4 kB | Preview Download |
System files
(30.7 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Реактиметр с аналоговым и импульсным каналами измерения мощности реактора
Publishing Information
- Imprint Pagination
- 15 p.
- Report number
- KIYaI--88-53
INIS
- Country of Publication
- Ukraine
- Country of Input or Organization
- Ukraine
- INIS RN
- 23048938
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- ANALOG SYSTEMS; ANALOG-TO-DIGITAL CONVERTERS; BENCH-SCALE EXPERIMENTS; FLOWSHEETS; MEASURING METHODS; OPERATIONAL AMPLIFIERS; PULSE DISCRIMINATORS; PULSE SHAPERS; REACTIVITY METERS; SENSITIVITY; WWR TYPE REACTORS
- Descriptors DEC
- AMPLIFIERS; DIAGRAMS; DISCRIMINATORS; ELECTRONIC CIRCUITS; ELECTRONIC EQUIPMENT; ENRICHED URANIUM REACTORS; EQUIPMENT; INFORMATION; PULSE CIRCUITS; REACTORS; TANK TYPE REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS