Published July 1999 | Version v1
Report Open

Temperature distributions of a conductively heated filament

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

Description

Temperature distributions of a heated filament were measured. A W-Re(5%) filament (0.25 mm in diameter, 24.7 mm in length) was conductively heated by currents between 5A and 7A with a DC power supply, and the surface of the filament was imaged with a charge coupled device (CCD) camera through a monochromatic filter. The spectral radiation intensity at the filament center region was almost uniform. Since the temperature distribution was also uniform and the energy loss by thermal conduction was negligible, temperature in this region was determined from the energy balance between applied power and radiation loss. Temperature distribution of the filament was determined based on the Planck's law of radiation from the spectral radiation intensity ratio of the filament surface using obtained temperature as a reference. It was found that temperature distribution of a filament was easily measured by this method. (author)

Availability note (English)

Available from INIS in electronic form

Files

30061179.pdf

Files (454.1 kB)

Name Size Download all
md5:1fb6687a7406c0de705bd0a78103034b
454.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
15 p.
Report number
JAERI-Tech--99-050