Published January 1984 | Version v1
Report Restricted

Material open test assembly processing at the FFTF's IEM cell

Description

The Interim Examination and Maintenance (IEM) Cell is a vertical hot cell located within the containment dome of the Fast Flux Test Facility (FFTF). The cell has two basic functions: (1) to perform disassembly/reassembly and nondestructive testing on radioactive, sodium-wetted reactor components, and (2) to provide a shielded work volume where radioactive, sodium-wetted reactor and refueling equipment can be repaired and maintained. One of the recent FFTF experiments processed through the IEM Cell was the Material Open Test Assembly (MOTA). This paper describes the disassembly and reassembly of the MOTA test assembly

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE84010317.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
Interim examination and maintenance

Publishing Information

Imprint Pagination
5 p.
Report number
HEDL-SA--3092-S

Conference

Title
Annual meeting of the American Nuclear Society.
Dates
3-8 Jun 1984.
Place
New Orleans, LA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16003219
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FFTF REACTOR; HOT CELLS; IRRADIATION CAPSULES
Descriptors DEC
EPITHERMAL REACTORS; EQUIPMENT; FAST REACTORS; LABORATORY EQUIPMENT; LIQUID METAL COOLED REACTORS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; SODIUM COOLED REACTORS; TEST REACTORS

Optional Information

Secondary number(s)
CONF-840614--46.