A small reactor inter header break for Embalse nuclear power plant with loss of electrical supply

  • 1. Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

Description

A small reactor inlet header break was studied for Embalse Nuclear Power Station. The initial leakage rate was 55 kg/s. A low pressure trip was reached. As a consequence, electrical power supply was assumed to be lost. Results show that in 30 minutes operator actions must follow in order to avoid high fuel temperatures. (author)

Additional details

Additional titles

Original title (Spanish)
Rutura pequena en colector de entrada del sistema primario de transporte de calor de la central nuclear de Embalse con perdida de suministro electro

Publishing Information

Imprint Title
Proceedings of the 4. General Congress on Nuclear Energy. v. 1
Imprint Pagination
496 p.
Journal Page Range
p. 119-124.

Conference

Title
4. General Congress on Nuclear Energy.
Dates
5-9 Jul 1992.
Place
Rio de Janeiro, RJ (Brazil).

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
23079448
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ELECTRIC CONTROLLERS; FUEL INTEGRITY; HEAT TRANSFER; RA-0 REACTOR; REACTOR ACCIDENTS
Descriptors DEC
ACCIDENTS; CONTROL EQUIPMENT; ENERGY TRANSFER; EQUIPMENT; EXPERIMENTAL REACTORS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; TANK TYPE REACTORS; ZERO POWER REACTORS

Optional Information

Notes
Imprint:Anais do 4. Congresso Geral de Energia Nuclear. v. 1.