Published 1992
| Version v1
Miscellaneous
A small reactor inter header break for Embalse nuclear power plant with loss of electrical supply
Creators
- 1. Comision Nacional de Energia Atomica, Buenos Aires (Argentina)
Description
A small reactor inlet header break was studied for Embalse Nuclear Power Station. The initial leakage rate was 55 kg/s. A low pressure trip was reached. As a consequence, electrical power supply was assumed to be lost. Results show that in 30 minutes operator actions must follow in order to avoid high fuel temperatures. (author)
Additional details
Additional titles
- Original title (Spanish)
- Rutura pequena en colector de entrada del sistema primario de transporte de calor de la central nuclear de Embalse con perdida de suministro electro
Publishing Information
- Imprint Title
- Proceedings of the 4. General Congress on Nuclear Energy. v. 1
- Imprint Pagination
- 496 p.
- Journal Page Range
- p. 119-124.
Conference
- Title
- 4. General Congress on Nuclear Energy.
- Dates
- 5-9 Jul 1992.
- Place
- Rio de Janeiro, RJ (Brazil).
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 23079448
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ELECTRIC CONTROLLERS; FUEL INTEGRITY; HEAT TRANSFER; RA-0 REACTOR; REACTOR ACCIDENTS
- Descriptors DEC
- ACCIDENTS; CONTROL EQUIPMENT; ENERGY TRANSFER; EQUIPMENT; EXPERIMENTAL REACTORS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; TANK TYPE REACTORS; ZERO POWER REACTORS
Optional Information
- Notes