Description

This Acceptance Test Report documents compliance with the requirements of specification WHC-S-0251, Rev.0 and ECNs 613530 and 606113. The equipment was tested according to WHC-SD-WM-ATP-104. The equipment tested is a Breathing Air Supply Trailer purchased as a design and fabrication procurement activity. The ATP was written by the Seller and was performed by the Seller with representatives of the Westinghouse Hanford Company witnessing portions of the test at the Seller's location

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE97052605; NTIS; US Govt. Printing Office Dep.

Files

28074913.pdf

Files (820.2 kB)

Name Size Download all
md5:44cb369ec1cb7ac21a2e5236a5d5a77d
820.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
44 p.
Report number
WHC-SD--WM-ATR-104

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
28074913
Subject category
S42: ENGINEERING; S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
Descriptors DEI
AIR; BREATH; COMPRESSED AIR; HANFORD RESERVATION; RESPIRATORS; VEHICLES
Descriptors DEC
COMPRESSED GASES; FLUIDS; GASES; NATIONAL ORGANIZATIONS; US DOE; US ORGANIZATIONS