Breathing air trailer acceptance test report
Description
This Acceptance Test Report documents compliance with the requirements of specification WHC-S-0251, Rev.0 and ECNs 613530 and 606113. The equipment was tested according to WHC-SD-WM-ATP-104. The equipment tested is a Breathing Air Supply Trailer purchased as a design and fabrication procurement activity. The ATP was written by the Seller and was performed by the Seller with representatives of the Westinghouse Hanford Company witnessing portions of the test at the Seller's location
Availability note (English)
MF available from INIS under the Report Number; Also available from OSTI as DE97052605; NTIS; US Govt. Printing Office Dep.Files