Monte-Carlo model development for evaluation of current clinical target volume definition for heterogeneous and hypoxic glioblastoma
Creators
- 1. Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA (Australia)
- 2. School of Chemistry and Physics, University of Adelaide, Adelaide, SA (Australia)
Description
Clinical target volume (CTV) determination may be complex and subjective. In this work a microscopic-scale tumour model was developed to evaluate current CTV practices in glioblastoma multiforme (GBM) external radiotherapy. Previously, a Geant4 cell-based dosimetry model was developed to calculate the dose deposited in individual GBM cells. Microscopic extension probability (MEP) models were then developed using Matlab-2012a. The results of the cell-based dosimetry model and MEP models were combined to calculate survival fractions (SF) for CTV margins of 2.0 and 2.5 cm. In the current work, oxygenation and heterogeneous radiosensitivity profiles were incorporated into the GBM model. The genetic heterogeneity was modelled using a range of α/β values (linear-quadratic model parameters) associated with different GBM cell lines. These values were distributed among the cells randomly, taken from a Gaussian-weighted sample of α/β values. Cellular oxygen pressure was distributed randomly taken from a sample weighted to profiles obtained from literature. Three types of GBM models were analysed: homogeneous-normoxic, heterogeneous-normoxic, and heterogeneous-hypoxic. The SF in different regions of the tumour model and the effect of the CTV margin extension from 2.0–2.5 cm on SFs were investigated for three MEP models. The SF within the beam was increased by up to three and two orders of magnitude following incorporation of heterogeneous radiosensitivities and hypoxia, respectively, in the GBM model. However, the total SF was shown to be overdominated by the presence of tumour cells in the penumbra region and to a lesser extent by genetic heterogeneity and hypoxia. CTV extension by 0.5 cm reduced the SF by a maximum of 78.6 ± 3.3%, 78.5 ± 3.3%, and 77.7 ± 3.1% for homogeneous and heterogeneous-normoxic, and heterogeneous hypoxic GBMs, respectively. Monte-Carlo model was developed to quantitatively evaluate SF for genetically heterogeneous and hypoxic GBM with two CTV margins and three MEP distributions. The results suggest that photon therapy may not provide cure for hypoxic and genetically heterogeneous GBM. However, the extension of the CTV margin by 0.5 cm could be beneficial to delay the recurrence time for this tumour type due to significant increase in tumour cell irradiation. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/61/9/3407Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 61
- Journal Issue
- 9
- Journal Page Range
- p. 3407-3426
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47107381
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ANOXIA; DOSIMETRY; EVALUATION; GLIOMAS; IRRADIATION; MONTE CARLO METHOD; PROBABILITY; RADIATION DOSES; RADIOSENSITIVITY; RADIOTHERAPY; SURVIVAL CURVES
- Descriptors DEC
- CALCULATION METHODS; DISEASES; DOSES; MEDICINE; NEOPLASMS; NERVOUS SYSTEM DISEASES; NUCLEAR MEDICINE; RADIOLOGY; SENSITIVITY; THERAPY