Journal article
Sodium fluorescence method and apparatus for on-site test of nuclear HEPA filtering
Creators
- 1. College of Mechanical Engineering and Automatization, North University of China, Taiyuan (China)
Description
Sodium fluorescence method is an important method for on-site test of nuclear HEPA filters. In this paper, the test principle of sodium fluorescence method, test data recording, test data processing and a sodium fluorescence aerosol generator developed in co-operation with Institute of Radiation Protection of China is introduced. Practice in the past a few years proved that the sodium fluorescence aerosol generator is reliable and effective, and is ready for wide applications. (authors)