Published 1982 | Version v1
Report Open

Conceptural design of multipurpose sodium test loop

  • 1. Korea Advanced Energy Research Inst., Seoul (Republic of Korea)

Description

This report describes the conceptural design of the multipurpose sodium test loop (MSTL). This MSTL consists mainly of impurity control and measurement system, corrosion and masstransfer system and heat transfer system. Problems associated with liquid sodium coolant will be studied and operating experiences will be obtained by the use of this facility. This technology will be used to evaluate safety and reliability of large sodium facility in the future. The total cost excluding the cost of building construction is estimated to 175 thousand dollars. (Author)

Availability note (English)

MF available from INIS under the Report Number.

Files

13708672.pdf

Files (2.2 MB)

Name Size Download all
md5:9d6b7ed13ba9cfe2630cab4901f5cfde
2.2 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
61 p.
Report number
KAERI/RR--281/81

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
13708672
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
COOLANT LOOPS; COOLANTS; CORROSION; HEAT TRANSFER; IMPURITIES; LIQUID METALS; MASS TRANSFER; SODIUM; SPECIFICATIONS
Descriptors DEC
ALKALI METALS; CHEMICAL REACTIONS; ELEMENTS; ENERGY TRANSFER; FLUIDS; LIQUIDS; METALS