Published 2011 | Version v1
Book

Analysing The Thermalhydraulic Parameters Of VVER-1000 Reactor For The Accident Of Steam Generator Tube Rupture

  • 1. Vietnam Agency for Radiation and Nuclear Safety, Hanoi (Viet Nam)

Description

To ensure the safety operation of nuclear power plant (NPP), a lot of postulated accident scenarios were considered and analysed. This research chose and analysed the accident of steam generator tube rupture (SGTR) under the actual plant conditions by using the simulation program PCTRAN. The SGTR accident is happen when the NPP is under operation with the steady state condition (power of 3000 MWth, primary pressure of 157 bar and secondary pressure of 63 bar). The accident is initiated by creating a break with equivalent diameter of 100 mm in the area of lower row heat exchanging tubes. The result of analysis is compared with the calculation of the Shariz University, Iran using the thermal hydraulics code RELAP5/mod3.2 and the report in the PSAR data of VVER-1000. This comparison shows that it is possible for using PCTRAN to analyse accidents of VVER-1000 reactor. (author)

Part of:
Proceedings of the 9th National Conference on Nuclear Science and Technology

Additional details

Additional titles

Original title (Vietnamese)
Phan tich tham so thuy nhiet cua lo phan ung VVER-1000doi voi tai nan vo ong binh sinh hoi

Publishing Information

Publisher
Science and Technics Publishing House
Imprint Place
Hanoi (Viet Nam)
Imprint Title
Proceedings of the 9"t"h National Conference on Nuclear Science and Technology
Imprint Pagination
1083 p.
Journal Page Range
p. 119-127

Optional Information

Notes
4 refs, 10 figs, 3 tabs