Published 1977 | Version v1
Report Restricted

Dynamic boiling tests in a 19-pin simulated LMFBR fuel assembly

Description

A series of quasi-steady state tests were made to study dynamic boiling and to determine a boiling region which would not lead to immediate dryout and pin failure in the Thermal-Hydraulic Out-of-Reactor Safety (THORS) Facility (previously the Fuel Failure Mockup), an engineering-scale sodium loop for testing simulated LMFBR fuel assemblies at normal and off-normal operating conditions. These tests were made on an assembly consisting of 19 electrically heated pins of the same configuration as FFTF fuel. Approximately 50 flow transients were so conducted to boiling or near boiling over a range of flows and powers. Dryout occurred at three test conditions

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
22 p.
Report number
CONF-771109--77

Conference

Title
ANS winter meeting.
Dates
27 Nov - 2 Dec 1977.
Place
San Francisco, CA, USA.