Purpose: Paclitaxel-coated balloon catheters inhibit restenosis after coronary and peripheral angioplasty (PCI,PTA). The aim of this study was to investigate paclitaxel plasma levels and laboratory parameters following PTA with paclitaxel-coated balloons (PCB) in peripheral arteries. Materials and Methods: This single treatment arm, multicenter study included 14 patients with Rutherford stage 1 - 5 with occlusions of up to 5 cm or ≥ 70 % diameter stenosis of the superficial femoral or popliteal arteries (SFA, PA). PTA was performed using up to three PCB catheters. The paclitaxel plasma levels and safety laboratory parameters were determined by collecting blood samples pre-intervention, immediately post-intervention, at 0.5, 1, 2, 4, 8, 24 hours and 1 and 4 weeks post-intervention (p. i.). Vital signs were monitored to assess clinical safety. Results: PTA was performed successfully in all patients. Paclitaxel plasma levels were always below a level and duration known to cause systemic side effects. A mean peak paclitaxel plasma level (40 ng/ml) was reached immediately p. i. and decreased rapidly below detectable levels in more than half of the patients already 2 hours p. i. The paclitaxel plasma concentrations returned to values below detectable levels at 24 hours p. i. in all patients. Laboratory parameters and vital signs did not give any reason for safety concerns. No adverse events associated with balloon coating were observed. Conclusion: The results of 14 patients with peripheral arterial occlusive disease show no systemic bioavailability of paclitaxel > 24 hours after PTA with one or more PCB catheters, indicating that the PCB catheter is safe with regard to possible systemic effects. (orig.)

Additional details

Publishing Information

Journal Title
RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
Journal Volume
183
Journal Issue
5
Journal Page Range
p. 448-455
ISSN
1438-9029
CODEN
RFGNDO

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
42084029
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ARTERIES; BLOOD PLASMA; EPITHELIUM; FEMUR; VASCULAR DISEASES
Descriptors DEC
ANIMAL TISSUES; BIOLOGICAL MATERIALS; BLOOD; BLOOD VESSELS; BODY; BODY FLUIDS; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DISEASES; MATERIALS; ORGANS; SKELETON