68Ge/68Ga composite CeO2-PAN generator. Preparation, testing and use

  • 1. Czech Technical University in Prague, Prague (Czech Republic). Department of Nuclear Chemistry, Faculty of Nuclear Sciences and Physical Engineering

Description

This work is focused on the testing of a new 68Ge/68Ga radionuclide generator based on cerium dioxide in polyacrylonitrile beads. During an 18-month period, parameters of elution were monitored, and basic radiolabelling studies were carried out. As current commercial solutions deal with high elution volume and low long-term stability, the constructed system offers several improvements. The composite sorbent provides uniformity of active component dispersion and high capacity for 68Ge. It enables minimal elution volume without fractionation (up to 1.8 mL) and stability of 68Ge breakthrough (under 0.001%) after initial period of wash-out and low cerium leakage (under 5 ppm). (author)

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
333
Journal Issue
11
Journal Page Range
p. 5545-5553
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Notes
47 refs.