Published November 11, 1985 | Version v1
Report Open

Plasma-potential diagnostic (PPD) hardware used on the Tandem Mirror Experiment-Upgrade (TMX-U)

Description

The PPD is an instrument used to indirectly measure the potential of the center-cell plasma of TMX-U. Thallium ions are injected at energies of about 60 keV from an ion gun capable of 80 kV operation. The singly charged ions collide with plasma electrons and generate double-charged ions. Ions in the higher charge state exit the plasma and are detected in an electrostatic energy analyzer. From measurements of the injected ion energy and the output ion energy one can determine the plasma potential in the ionization region. The absolute potential measurements required careful calibrations of the energy analyzer. Hardware and techniques for calibration of the energy analyzer are discussed. 2 refs., 4 figs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE86005197.

Files

17041778.pdf

Files (179.5 kB)

Name Size Download all
md5:1f9ec5640080f2e28a44271c41fdb8a2
179.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
UCRL--92519

Conference

Title
11. symposium on engineering problems in fusion research.
Dates
18-22 Nov 1985.
Place
Austin, TX (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
17041778
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CALIBRATION; ELECTRIC POTENTIAL; ELECTROSTATIC ANALYZERS; ON-LINE CONTROL SYSTEMS; PLASMA DIAGNOSTICS; THALLIUM IONS; TMX DEVICES
Descriptors DEC
ATOMIC IONS; BEAM ANALYZERS; CHARGED PARTICLES; CONTROL SYSTEMS; IONS; MAGNETIC MIRRORS; ON-LINE SYSTEMS; OPEN PLASMA DEVICES; TANDEM MIRRORS; THERMONUCLEAR DEVICES

Optional Information

Secondary number(s)
CONF-851102--71.