Published May 8, 2014 | Version v1
Journal article

Diffusion-weighted MR imaging of transplanted kidneys: Preliminary report

  • 1. Department of Radiology and Diagnostic Imaging, Nicolaus Copernicus University, Collegium Medicum, Bydgoszcz (Poland)
  • 2. Department of General Surgery and Transplantology, Nicolaus Copernicus University, Collegium Medicum, Bydgoszcz (Poland)

Description

An aim of this study was to assess the feasibility of DWI in the early period after kidney transplantation. We also aimed to compare ADC and eADC values in the cortex and medulla of the kidney, to estimate image noise and variability of measurements, and to verify possible relation between selected labolatory results and diffusion parameters in the transplanted kidney. Examinations were performed using a 1.5 T MR unit. DWI (SE/EPI) was performed in the axial plane using b-values of 600 and 1000. ADC and eADC measurements were performed in four regions of interest within the renal cortex and in three regions within the medulla. Relative variability of results and signal-to-noise ratio (SNR) were calculated. The analysis included 15 patients (mean age 52 years). The mean variability of ADC was significantly lower than that of eADC (6.8% vs. 10.8%, respectively; p<0.0001). The mean variability of measurements performed in the cortex was significantly lower than that in the medulla (6.2% vs. 11.5%, respectively; p<0.005). The mean SNR was higher in the measurements using b600 than b1000, it was higher in ADC maps than in the eADC maps, and it was higher in the cortex than in the medulla. ADC and eADC measured at b1000 in the cortex were higher in the group of the patients with eGFR ≤30 ml/min./1.73 m2 as compared to patients with eGFR >30 ml/min./1.73 m2 (p<0.05). Diffusion-weighted imaging of transplanted kidneys is technically challenging, especially in patients in the early period after transplantation. From a technical point of view, the best quality parameters offer quality ADC measurement in the renal cortex using b1000. ADC and eADC values in the renal cortex measured at b1000 present a relationship with eGFR

Availability note (English)

Available from http://dx.doi.org/10.12659/PJR.890502; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4018246

Additional details

Publishing Information

Journal Title
Polish Journal of Radiology
Journal Volume
79
Journal Page Range
p. 94-98
ISSN
1733-134X

INIS

Country of Publication
Poland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47031374
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ANALOG-TO-DIGITAL CONVERTERS; BIOMEDICAL RADIOGRAPHY; KIDNEYS; NMR IMAGING; PATIENTS; SIGNAL-TO-NOISE RATIO
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; ELECTRONIC EQUIPMENT; EQUIPMENT; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY

Optional Information

Copyright
Copyright (c) Pol J Radiol, 2014
Notes
PMCID: PMC4018246; PMID: 24826200; PUBLISHER-ID: 890502; OAI: oai:pubmedcentral.nih.gov:4018246; This is an open access article. Unrestricted non-commercial use is permitted provided the original work is properly cited.