Performance study of monochromatic synchrotron X-ray computed tomography using a linear array detector
Creators
- 1. Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine
Description
Monochromatic x-ray computed tomography (CT) using synchrotron radiation (SR) is being developed for detection of non-radioactive contrast materials at low concentration for application in clinical diagnosis. A new SR-CT system with improved contrast resolution, was constructed using a linear array detector which provides wide dynamic ranges and a double monochromator. The performance of this system was evaluated in a phantom and a rat model of brain ischemia. This system consists of a silicon (111) double crystal monochromator, an x-ray shutter, an ionization chamber, x-ray slits, a scanning table for the target organ, and an x-ray linear array detector. The research was carried out at the BLNE-5A bending magnet beam line of the Tristan Accumulation Ring in KEK, Japan. In this experiment, the reconstructed image of the spatial-resolution phantom clearly showed the 1 mm holes. At 1 mm slice thickness, the above K-edge image of the phantom showed contrast resolution at the concentration of 200 μg/ml iodine-based contrast materials whereas the K-edge energy subtraction image showed contrast resolution at the concentration of 500 μg/ml contrast materials. The cerebral arteries filled with iodine microspheres were clearly revealed, and the ischemic regions at the right temporal lobe and frontal lobe were depicted as non-vascular regions. The measured minimal detectable concentration of iodine on the above K-edge image is about 6 times higher than the expected value of 35.3 μg/ml because of the high dark current of this detector. Thus, the use of a CCD detector which is cooled by liquid nitrogen to improve the dynamic range of the detector, is being under construction. (author)
Additional details
Publishing Information
- Journal Title
- Medical Imaging Technology
- Journal Volume
- 15
- Journal Issue
- 5
- Journal Page Range
- p. 615-624.
- ISSN
- 0288-450X
- CODEN
- MITEET
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 28074504
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRAIN; CAT SCANNING; IONIZATION CHAMBERS; PERFORMANCE; PHANTOMS; RATS; SPATIAL RESOLUTION; X-RAY DETECTION
- Descriptors DEC
- ANIMALS; BODY; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; DETECTION; MAMMALS; MEASURING INSTRUMENTS; MOCKUP; NERVOUS SYSTEM; ORGANS; RADIATION DETECTION; RADIATION DETECTORS; RESOLUTION; RODENTS; STRUCTURAL MODELS; TOMOGRAPHY; VERTEBRATES