We have experimentally determined the electron collisional excitation cross-sections for several 3d→4f and 3d→5f excitations in Ni- to Ge-like Au at energies of ∼ 0.4, 1, 2, and 3 keV above threshold energy, ET, for the 3d→4f excitations (ET ∼ 2.5 keV) and ∼ 0.2, 1, and 2 keV above threshold energy for the 3d→5f excitations (ET ∼ 3.3 keV). The cross-section measurements are possible by using the GSFC micro-calorimeter to record emission spectra from beam plasmas created in the Livermore EBIT-I electron beam ion trap. The cross-sections are experimentally determined from the ratio of the measured intensities of the collisionally excited lines to the intensities of the radiative recombination lines in monoenergetic electron distribution EBIT-I plasmas. The effects of polarization and Auger processes in the beam plasmas are accounted for in the cross-section determination. Experimentally determined cross-sections are compared with those from HULLAC, DWS, and FAC calculations. The measurements exhibit significant differences with the calculations of these excitation cross-sections. (authors)

Additional details

Identifiers

EISSN
1208-6045;
DOI
10.1139/cjp-2023-0121;

Publishing Information

Journal Title
Canadian Journal of Physics
Journal Volume
102
Journal Issue
3
Journal Page Range
152-167
ISSN
0008-4204
CODEN
CJPHAD