Published January 1, 2012 | Version v1
Report

Titanium tritide radioisotope heat source development: palladium-coated titanium hydriding kinetics and tritium loading tests

  • 1. Savannah River National Labs, Aiken, SC (United States)

Description

We have found that a 180 nm palladium coating enables titanium to be loaded with hydrogen isotopes without the typical 400-500 C vacuum activation step. The hydriding kinetics of Pd coated Ti can be described by the Mintz-Bloch adherent film model, where the rate of hydrogen absorption is controlled by diffusion through an adherent metal-hydride layer. Hydriding rate constants of Pd coated and vacuum activated Ti were found to be very similar. In addition, deuterium/tritium loading experiments were done on stacks of Pd coated Ti foil in a representative-size radioisotope heat source vessel. The experiments demonstrated that such a vessel could be loaded completely, at temperatures below 300 C, in less than 10 hours, using existing department-of-energy tritium handling infrastructure.

Availability note (English)

Available from http://prod.sandia.gov/sand_doc/2012/120232.pdf; PURL: https://www.osti.gov/servlets/purl/1035341/

Additional details

Publishing Information

Imprint Pagination
40 p.
Report number
SAND--2012-0232

Optional Information

Contract/Grant/Project number
AC04-94AL85000
Notes
doi 10.2172/1035341
Funding organization
US Department of Energy (United States)