Published August 2017 | Version v1
Miscellaneous

Insulation performance of safety-related cables for nuclear power plants under simulated severe accident conditions

  • 1. Nuclear Regulation Authority, Secretariat of the Nuclear Regulation Authority, Tokyo (Japan)
  • 2. Waseda Univ., Tokyo (Japan)

Description

To examine electrical insulation behavior of cables under severe accident environments, safety-related low voltage cables used as 'severe accident management equipment' were subjected to the test at 155degC, which simulated highest assumed temperature when proper accident management measures are taken. In addition, insulation resistance was measured for the cables during steam exposure in the test. As a result, all the cables passed the acceptance criteria of voltage withstand test prescribed in the JNES Guide. The minimum resistivity of the cables during the test at 155degC was around 108 Ωm, confirming that the cables have a sufficient insulation performance. (author)

Part of:
Proceedings of the 14th annual meeting of Japan Society of Maintenology

Additional details

Additional titles

Original title (Japanese)
重大事故模擬環境下における原子力発電所用安全系ケーブルの絶縁性能

Publishing Information

Imprint Title
Proceedings of the 14th annual meeting of Japan Society of Maintenology
Imprint Pagination
580 p.
Journal Page Range
p. 395-399

Conference

Title
14. annual meeting of Japan Society of Maintenology
Dates
2-4 Aug 2017
Place
Matsuyama, Ehime (Japan)

Optional Information

Notes
15 refs., 4 figs., 2 tabs. Imprint:#65E5##672C##4FDD##5168##5B66##4F1A##7B2C#14#56DE##5B66##8853##8B1B##6F14##4F1A##8981##65E8##96C6#