Published December 1996 | Version v1
Report

Analysis of transients caused by control assembly ejection during full and 55% nominal power in selected conservative configurations of a WWER-440/213 NPP

Description

Processes caused by ejection of an off-center located control assembly in the 6th group of emergency and control assemblies from a depth of 125 cm from the bottom edge of the reactor core were analyzed. The initial configurations of the reactor core were chosen in accordance with the current and prospectively expected fuel configurations at the Dukovany nuclear power plant. The use of assemblies at a 3.6% enrichment and the replacement of the steel lattices by zirconium alloy lattices were taken into account. The DYN3D/M3 code was employed for the calculations. (M.D.)

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic

Additional details

Additional titles

Original title (Czech)
Analyza prechodovych procesu zpusobenych vystrelenim regulacni kazety pri plnem a 55% nominalnim vykonu ve vybranych konzervativnich konfiguracich JE VVER-440/213

Publishing Information

Imprint Pagination
[78 p.]
Report number
UJV--10863-R,T

Optional Information

Notes
4 tabs., 58 figs., 11 refs.