Published November 1981 | Version v1
Report Open

Neutron dosimetry and spectrometry with Bonner spheres. Working out a log-normal reference matrix

Description

From the experimental and theoretical studies made upon the BONNER's spheres System with a I6Li(Eu) crystal and with a miniaturized 3He counter we get the normalized energy response functions R*sub(i)(E). This normalization is obtained by the mathematization of the Resolution Function R*(i,E) in the Log-Normal distribution hypothesis to mono energetic neutrons given in April 1976 to the International Symposium on Californium 252. The fit of the Log-Normal Hypothesis with the experimental and Theoretical data is very satisfactory. The parameter's tabulated values allow a precise interpolation, at all energies between 0.4 eV and 15 MeV and for all spheres diameters between 2 and 12 inches, of the discretized R*sub(ij) Reference Matrix for the applications to neutron dosimetry and spectrometry

Availability note (English)

MF available from INIS under the Report Number.

Abstract (French)

A partir des etudes experimentales et theoriques effectuees sur le Systeme des Spheres de BONNER avec un cristal I6Li(Eu) et le compteur miniaturise 3He developpe du CEA nous obtenons les fonctions de reponse en energie des spheres R*sub(i)(E) normalisees. Cette normalisation est effectuee par la mathematisation de la Fonction de Resolution R*(i,E) dans l'hypothese des distributions Log-Normales aux neutrons monocinetiques donnee en Avril 1976 au Congres International sur le Californium 252. L'accord de l'hypothese Log-Normale avec les donnees experimentales et theoriques est tres satisfaisant. Les valeurs que nous donnons tabulees des parametres permettent une interpolation precise, a toute energie entre 0,4 eV et 15 MeV et pour tous les diametres des spheres entre 2 et 12 pouces, de la Matrice de Reference discretisee R*sub(ij) en vue des applications a la dosimetrie et a la spectrometrie neutroniques

Files

13692740.pdf

Files (923.2 kB)

Name Size Download all
md5:b60cfa6041e9b3fb062ed9aaa7583749
923.2 kB Preview Download

Additional details

Additional titles

Original title (French)
Dosimetrie et spectrometrie neutroniques avec les spheres de Bonner. Etablissement d'une matrice log-normale de reference

Publishing Information

Imprint Pagination
35 p.
Report number
CEA-N--2241