TIME RESOLVED X-RAY SPOT DIAGNOSTIC

Description

A diagnostic was developed for the determination of temporal history of an X-ray spot. A pair of thin (0.5 mm) slits image the x-ray spot to a fast scintillator which is coupled to a fast detector, thus sampling a slice of the X-Ray spot. Two other scintillator/detectors are used to determine the position of the spot and total forward dose. The slit signal is normalized to the dose and the resulting signal is analyzed to get the spot size. The position information is used to compensate for small changes due to spot motion and misalignment. The time resolution of the diagnostic is about 1 ns and measures spots from 0.5 mm to over 3 mm. The theory and equations used to calculate spot size and position are presented, as well as data. The calculations assume a symmetric, Gaussian spot. The spot data is generated by the ETA II accelerator, a 2kA, 5.5 MeV, 60 ns electron beam focused on a Tantalum target. The spot generated is typically about 1 mm FWHM. Comparisons are made to an X-ray pinhole camera which images the X-Ray spot (in 2D) at four time slices

Availability note (English)

Available from OSTI as DE00883576; PURL: https://www.osti.gov/servlets/purl/883576-fGD4sf/

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
UCRL-CONF--212089

Conference

Title
21. Biennial Particle Accelerator Conference (PAC05)
Dates
16-20 May 2005
Place
Knoxville, TN (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
37089134
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATORS; CAMERAS; ELECTRON BEAMS; PHOSPHORS; SAMPLING; TANTALUM; TIME RESOLUTION
Descriptors DEC
BEAMS; ELEMENTS; LEPTON BEAMS; METALS; PARTICLE BEAMS; REFRACTORY METALS; RESOLUTION; TIMING PROPERTIES; TRANSITION ELEMENTS

Optional Information

Contract/Grant/Project number
W-7405-ENG-48
Notes
PDF-FILE: 6; SIZE: 0.6 MBYTES
Funding organization