Published April 6, 2005 | Version v1
Journal article

Source of Negative Hydrogen Ions with Hot Cathode

  • 1. Budker Institute of Nuclear Physics, Novosibirsk 630090 (Russian Federation)

Description

In the report an H- ion source with following parameters is described. Ion energy is up to 30 keV, current is up to 5 mA, pulse duration varies from 1 to tens microseconds. H- ions are produced in magnetron discharge near a hot cathode surface made of LaB6 or IrCe alloy, which is 6 mm in diameter. H- ions are extracted through 0.8x7 mm slot. An electromagnetic valve was used for pulsed gas feed. Ion current depends on discharge current that in turn is defined by cathode temperature, discharge voltage, and hydrogen pressure. Two permanent magnets fixed on iron yoke generate magnetic field for magnetron discharge. There are a magnetic and electrostatic corrections of trajectories of extracted H- ions. The H- ion source has been used as an injector for tandem accelerator with the following proton beam parameters: energy is 1.4 MeV, current is 3mA, and pulse duration is 2 microseconds. Simulation of ion beam trajectories in the source, transport channel, and tandem accelerator shows good correlation with experiments

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
763
Journal Issue
1
Journal Page Range
p. 275-281
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
10. international symposium on production and neutralization of negative ions and beams
Dates
14-17 Sep 2004
Place
Kiev (Ukraine)

Optional Information

Notes
(c) 2005 American Institute of Physics