Published May 2004 | Version v1
Report Open

A study on design guidelines for the icons used in nuclear power plants

  • 1. KAERI, Taejon (Korea, Republic of)
  • 2. Suwon Univ., Suwon (Korea, Republic of)

Description

In this project, advantages and disadvantages of icons on electronic displays were analyzed, and design procedures, design evaluation principles, and design guidelines for icons on electronic displays were developed. In addition, as design guidelines for special effects applicable to icons on electronic displays, guidelines for color coding, flashing, and 3-dimensional effects were developed. A questionnaire survey was performed to investigate how NPP operators consider methods representing icons on electronic displays (such as colors, dynamic effects, and 3-dimensional effects) compared to methods representing icons by using outlines in the P and ID drawings. NPP operators' preference of the icons designed in accordance with icon design guidelines to the icons without considering the guidelines was also investigated

Availability note (English)

Available from INIS in electronic form; Also available from Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

Files

36095392.pdf

Files (680.6 kB)

Name Size Download all
md5:2f6bf1985281bc15a161c71377d6c40c
680.6 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
64 p.
Report number
KAERI/TR--2758/2004

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
36095392
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
COMPUTERS; DESIGN; HUMAN FACTORS; NUCLEAR POWER PLANTS; REACTOR OPERATORS; RECOMMENDATIONS
Descriptors DEC
NUCLEAR FACILITIES; PERSONNEL; POWER PLANTS; THERMAL POWER PLANTS

Optional Information

Notes
10 refs, 26 figs, 3 tabs