Reliability and operating experience of the LAMPF 805-MHz rf system
Description
Over 850,000 hours have been accumulated on the klystrons and modulators that constitute the LAMPF 805-MHz rf system. The 1-1/4 MW klystrons, the floating-deck modulators, and the modulator triodes are described. The operating data are summarized, and the fault and failure modes are tabulated for the three major components of the system. The high-voltage processing and other maintenance required to keep this 86-kV system operating reliably are described. The tube failure rates, tube fault rates, and modulator fault rates are presented. The mean time to failures is greater than 56,500 h for the klystrons and greater than 40,600 h for the modulator triodes. The steps taken to produce such good reliability are discussed
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Publishing Information
- Imprint Pagination
- 6 p.
- Report number
- LA-UR--76-1666
Conference
- Title
- 6. European microwave conference.
- Dates
- 14 Sep 1976.
- Place
- Rome, Italy.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8290518
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ELECTRONIC CIRCUITS; FAILURES; KLYSTRONS; LAMPF LINAC; MAINTENANCE; OPERATION; RELIABILITY; RF SYSTEMS; TRIODE TUBES
- Descriptors DEC
- ACCELERATORS; CYCLIC ACCELERATORS; ELECTRON TUBES; ELECTRONIC EQUIPMENT; LINEAR ACCELERATORS; MESON FACTORIES; MICROWAVE EQUIPMENT; MICROWAVE TUBES
Optional Information
- Notes
- Available from NTIS. $3.50.
- Secondary number(s)
- CONF-760924--1.